Giddings & Lewis™ Ethernet EDI Driver

for the
FactoryLink Software System
(Formally called the Giddings & Lewis PiC900™ Ethernet EDI Driver)

The Giddings & Lewis™ Ethernet External Device Interface (EDI) Driver allows the user to configure bi directional communications between the FactoryLink Real Time Database and G&L controller(s). The Giddings & Lewis Ethernet EDI Driver uses a Giddings & Lewis proprietary protocol in UDP packets over a standard TCP/IP Ethernet network.

The Giddings & Lewis protocol allows access to any controller variables marked as Global in the PiCPro™ programmer. When the ladder is compiled and downloaded to the controller, PiCPro generates a data file containing information on these global variables. As part of the configuration of the Ethernet driver, the FactoryLink developer imports these files with a utility accessed from the standard FactoryLink configuration manager or developer studio. The imported global variables can then be used in read and write tables.

Read and write operations can occur at timed intervals, upon triggered conditions, or upon operator or system event requests. The Giddings & Lewis Ethernet EDI Driver controls the communication interface through information designated by the user in multiple configuration tables accessed from the FactoryLink Configuration Manager utility.

The FactoryLink Giddings & Lewis Ethernet EDI Driver is responsible for the following data transactions:

The FactoryLink Giddings & Lewis Ethernet EDI Driver provides the following configuration tables:


Specifications

Required FactoryLink Software

FactoryLink Multiplatform: Device Interface Software, FLxxx-DI

Note: Replace the "xxx" with the appropriate multiplatform preface and add the suffix -RT for runtime versions.

Required Hardware

Ethernet Adapter compatible with the operating system and the TCP/IP configuration.
In addition to the standard system components, the PiC900 and MMC require an Ethernet TCP/IP module be installed and configured while the MMC for PC requires the MMC for PC Support Software be installed and functional.

Required Software

Giddings & Lewis components:
1. PiCPro™ Version 10.1 or better for PiCs, 10.2 or better for MMCs, or 12.0 for MMC for PC.
2. Firmware that supports Ethernet TCP/IP communications in the Controller.
3. Ladder compiler with the following libraries: opinter.lib, io.lib, opc_enet.lib.
4. Ladder compiled with the following Function Blocks: OPC_10 or OPC_ENET.

Operating System software installed and configured to support UDP-TCP/IP communications over Ethernet.

Ordering Information

Part No: FLK-EDIGL9Exxx

Note: Replace "xxx" with the appropriate platform preface.

Software package includes 3-1/2" diskette and User's manual.

Pricing (U.S.Dollars)

PRICE EFFECTIVE 07/01/99 : List: $850.00 (PC Platforms)


Discount Policy

DASTEC Corporation, Herndon, Virginia USA
WWW.DASTEC.COM

Rev. 09/01/07